What was found
HYD VOLUME LOW. "A" SYSTEM REROUTE. VOL WAS BELOW 16% AND TEMP WAS RISING. UNLOADED "A" HYD PUMP AND PULLED HYD "B" PTU CONTROL CIRCUIT BREAKER. FOUND LT RESERVOIR LEAKING, REMOVED AND REPLACED RESERVOIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HYD VOLUME LOW. "A" SYSTEM REROUTE. VOL WAS BELOW 16% AND TEMP WAS RISING. UNLOADED "A" HYD PUMP AND PULLED HYD "B" PTU CONTROL CIRCUIT BREAKER. FOUND LT RESERVOIR LEAKING, REMOVED AND REPLACED RESERVOIR.