Service difficulty report · Relay · Raythn HAWKER800XP

Difficulty date
August 3, 2010
Submitted
August 5, 2010
Operation
Air carrier
Aircraft
N872QS
Make and model
Raythn HAWKER800XP
Aircraft serial
258472
Aircraft time
7,117 hours, 5,110 cycles
Part
Relay
Part number
MS24166D1
Condition
Malfunctioned
Location
Cockpit
Stage of operation
CL
How discovered
O
Nature of condition
G, S
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON INITIAL CLIMBOUT WHOLE RT SIDE AVIONICS WENT OUT (BOTH EFIS TUBES, NR 2 RADIO, NR 2 FMS). HEARD A POPPING SOUND NORMALY ASSOCIATED WITH WHEN IT TURNS ON AND OFF RADICALLY CYCLING. CHECKED CIRCUIT BREAKERS BUT ALL WERE IN. AFTER 5-6 MINS ALL SYS TURNED BACK ON. PLANE IN HEAVY RAIN DAY BEFORE. POWERED AVIONICS FOR 1 HR 30 MINUTES, NO DISCREPANCY NOTED. CREW STATES THE RT SIDE EFIS TOP & BOTTOM RT RTU & RT FMS LOST POWER. RT RADIO MASTER CONTROLS POWER TO THESE UNITS. REMOVED UNSERVICEABLE RELAY PN MS24166-DN1 SN N/A. INSTALLED A NEW RELAY PN MS24166-D1 SN N/A. OPS CHECK WAS FOUND TO BE SATISFACTORY. ACCOMPLISHED IAW WDM A8-6A-100.