What was found
AFTER TAKEOFF, DURING FLAP RETRACTION, FLAPS MOVED TO 0 AND STABILIZER STUCK BETWEEN UP AND TAKEOFF. YELLOW CAS MSG ILLUMINATED STABILIZER-FLAP FAIL. FOUND STAB ACTUATOR WAS OUT OF RIG, MANUALLY RAN STAB ACTUATOR FULL UP & FULL DOWN. NO BINDING NOTED. PERFORMED STAB ACTUATOR RIGGING & DWELL BOX RIGGING PROCEDURES IAW MM 27-06-01. PERFORMED FLAP & EMERGENCY FLAP OP'S TEST IAW MM 27-06-00. INSPECTED AN FLAP/ STAB DRIVE RODS & PILLOW BLOCKS, NO DEFECTS NOTED. OPS CHECKED GOOD.