What was found
ELEVATOR FEEL FAIL ILLUMINATED TWO TIMES DURING FLIGHT. REMAINING ON FOR 30-60 SECONDS EACH TIME. R & R Q FEEL SERVO ACTUATOR IAW CMP 273014. PERFORMED STALL PROTECTION AND Q FEEL ACTUATOR ADJUSTMENT TEST IAW CMP 273030. NO DEFECTS NOTED.