Service difficulty report · Condenser · Raythn HAWKER900XP

Difficulty date
August 31, 2013
Submitted
September 25, 2013
Operation
Air carrier
Aircraft
N897QS
Make and model
Raythn HAWKER900XP
Aircraft serial
HA0014
Aircraft time
3,041 hours, 2,142 cycles
Part
Condenser
Part number
8323712
Condition
Failed
Stage of operation
CR
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

BURNING ODOR IN COCKPIT, NOTICED FROM JUST AFTER TAKEOFF POWER APPLICATION UNTIL DISSIPATION AFTER 8-10 MINUTES. PERFORMED ENGINE MAINTENANCE RUN. RAN EACH ENGINE TO TAKEOFF POWER. NO NOTICEABLE OIL ODOR. WHILE TAXING BACK NOTICED MUSTY ODOR. SUGGESTED CHECK WATER SEPARATOR SOCKS. LOOSEN HOSE CLIP AND DISCONNECT FLEXIBLE PIPELINE FROM WATER SEPARATOR AND CLAMPS. REMOVED OUTLET SHELL, REPLACED GASKET AND CONDENSER WITH NEW ONE. INSTALLED CONDENSER AND GASKER. SECURED OUTLET SHELL TO INLET SHELL, CONNECTED AND TIGHTENED ALL CLIPS AND CLAMPS TO WATER SEPARATOR. WORK DONE IAW AMM 21-10-95 OPS CHECK NEED TO BE DONE. PERFORMED OPS CHECK/LEAK CHECK IAW MM 21-10-95 AND 49-00-00. NO LEAKS FOUND AND NO BURNING ODOR NOTED OPS CHECK GOOD.