What was found
RIGHT KEEL BEAM SPLICE CORRODED. REMOVED CORRODED KEEL BEAM SPLICE. ALL WORK DONE IAW SRM 51-40-03 & 51-40-00. INSTALLED NEW KEEL BEAM SPLICE IAW PRINT F2MA237015130-E01 & SRM 51-40-07. VERIFIED TORQUE APPLIED PROTECTION TO ALL EXPOSED FASTENERS IAW F2000 MM 20-60-00-370-812. APPLIED FIRST COAT DOME SEAL TO FASTENERS IN FUEL TANK IAW MM 20-32-00-340-802. APPLIED 2ND COAT OF SEALER TO FASTENERS IAW F2000 MM 20-32-00-340-802. APPLIED 3RD COAT OF SEALER TO FASTENERS IAW F2000 MM 20-32-00-349-802.