Service difficulty report · Unknown · Amd FALCON2000

Difficulty date
November 4, 2014
Submitted
November 7, 2014
Operation
Air carrier
Aircraft
N227QS
Make and model
Amd FALCON2000
Aircraft serial
127
Aircraft time
11,759 hours, 7,289 cycles
Part
Unknown
Condition
Odor
Location
Cockpit
Stage of operation
CR
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AN ACRID ODOR COMING FROM GLARE SHIELD VENTS ABOVE INSTRUMENT PANEL. RAN APU & USED APU BLEED AIR, RAN FOR SEVERAL MINUTES & NO ODOR WAS COMING FROM THE COCKPIT. RAN ENG 1 & 2 APPLIED BLEED AIR FROM BOTH ENGS FOR AN HOUR & NO ODOR WAS NOTED. ISOLATED ENG 1 BLEED AIR & LT FOR 1/2 HOUR, NO ODOR WAS NOTICED. ISOLATED BLEED AIR FOR ENG 2 FOR 1/2 HOUR, NO ODOR WAS NOTICED. NOTIFIED MX CONTROL COULD NOT DUPLICATE THE ODOR . ADVISED US TO BLOW COMPRESSOR AIR INTO ACM DRAIN LINE. LOCATED ACM DRAIN LINE & BLEW COMPRESSED AIR IN LINE. PERFORMED INSPECTION OF ACM FOR LEAKS OR LOOSE FITTINGS, NO DEFECTS FOUND. RAN APU BLEED AIR, NO ODOR NOTED. RAN ENG 1 & 2 WITH BLEED AIR, NO ODOR FOUND. RAN ONLY ENG 1 BLEED AIR, NO ODOR FOUND. RAN ENG 2 ONLY BLEED AIR, NO ODOR FOUND. NO ODOR CAN BE DETECTED. OPSS CHECKED GOOD. ALL WORK WAS DONE IAW MM 21-60-00.