Service difficulty report · Pressure Switch · Cessna 560CESSNA

Difficulty date
December 12, 2016
Submitted
December 16, 2016
Operation
Air carrier
Aircraft
N839QS
Make and model
Cessna 560CESSNA
Aircraft serial
5600690
Aircraft time
8,083 hours, 6,495 cycles
Part
Pressure Switch
Part number
GPP125066
Part serial
1633292
Condition
Failed
Location
Hyd System
Part time
4,948 hours, 3,971 cycles
Stage of operation
LD
How discovered
O
Nature of condition
J
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON SEAR EXTENSION LOW BRAKE PRESSURE AND ANTI-SKID ILLUMINATED. RAN APPROPRIATE CHECKLIST. DIVERTED. LANDING UNEVENTFUL. EMERGENCY BRAKING USED. BRAKE FLUID LEVEL WAS NORMAL. PRESSURE IN THE YELLOW BUT THAT WAS CHECKED AT LEAST 20 MIN AFTER LANDING. PERFORMED INITIAL INSPECTION NO SIGNS OF HYDRAULIC LEAKS FOUND. CHECK BRAKE RESERVOIR WITH HYDRAULIC LEVEL SHOWING ON THE SIGHT GLASS. PRESSURE GAUGE READING REMAINING PRESSURE. HYDRAULIC RESERVOIR SHOWS HYDRAULIC FLUID ON SIGHT GLASS. FOLLOWED TROUBLE SHOOT CHART FOR THE ANTI SKID BRAKE SYSTEM IAW AMM 32-42-00, CHART INDICATES THAT PRESSURE SWITCH. REMOVED AND REPLACED HIGH PRESSURE SWITCH WITH CUSTOMER SUPPLIED PART, IAW AMM 32-42-05. SERVICED BRAKE RESERVOIR IAW MM 12-12-02. BLEED ANTISKID BRAKE SYSTEM IAW MM 32-42-00. PERFORMED OPERATIONAL AND LEAK CHECK IAW MM 32-42-00. ALL CHECKS WERE PERFORMED SATISFACTORY.