Service difficulty report · Apu · Cndair CL6002B16

Difficulty date
December 13, 2017
Submitted
December 15, 2017
Operation
Air carrier
Aircraft
N225QS
Make and model
Cndair CL6002B16
Aircraft serial
6083
Aircraft time
1,105 hours, 625 cycles
Part
Apu
Condition
Smoke
Stage of operation
TO
How discovered
O
Nature of condition
B
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SOURCE - OIR REPORT: ON TAKEOFF ROLL, SMOKE IN COCKPIT, ABORTED TAKEOFF AT UNKNOWN SPEED. CLEARED IT OUT. ANTI ICE FLUID IN API INTAKE IS ASSUMED. TOOK OFF W ENGINE PROVIDING AIR AND PRESSURIZATION WITH NO ANOMALIES. NO FURTHER ISSUES. (CREW NEVER CONTACTED MAINTENANCE.) DUE TO MANAGEMENT REPORT RECEIVED WITH REPORTED SMOKE IN COCKPIT DUE TO DE-ICING FLUID IN APU INLET: NEXT FLIGHT-COMMUNICATED THAT WE WERE BREAKING THE AIRCRAFT TO THE SOC, BUT WAS NOT COMMUNICATED TO THE CREW THAT WE WERE STOPPING THE PLANE BEFORE THEY TOOK OFF. DISPATCH GOT THE CREW IN FLIGHT AND MADE THE DIVERSION TO CMH. AS A PRECAUTION: PERFORM GROUND RUNS WITH BOTH ENGINES AND APU. PERFORM OPERATIONAL CHECK OF THE ECS SYSTEM. NOTE ANY ABNORMALITIES IN THE CABIN AND COCKPIT. PERFORMED GROUND RUNS WITH BOTH ENGINES AND APU IAW CHALLENGER 650 MM 49-10-00 71-00-00. PERFORMED OPERATIONAL CHECK OF THE ECS SYSTEM IAW CHALLENGER 650 MM 21-61-00. NO ABNORMALITIES IN THE CABIN AND COCKPIT FOUND.