What was found
AT GEAR RETRACTION THE LO HYD LVL LIGHT ILLUMINATED. GEAR AND FLAPS RETRACTED NORMALLY WITH LIGHT ILLUMINATED. LIGHT WENT OUT WHEN GEAR WAS EXTENDED. GEAR AND FLAPS EXTENDED NORMALLY. POST FLIGHT INSPECTION SHOWS LOW HYDRAULIC FLUID LEVEL AND POSSIBLE BURNING SMELL. ****SUPPLEMENTAL INFORMATION: PERFORMED LANDING GEAR SWINGS & HYDRAULIC SYSTEM BLEED. NO FURTHER FAULTS FOUND AT THIS TIME. WORK PERFORMED IAW CE-560XL 32-01-00 & 29-11-00. SERVICED HYDRAULIC SYSTEM TO FULL IAW CE-560XL M/M 12-12-01. NO BURNING SMELL NOTICED.