Service difficulty report · Pump · Bombdr BD1001A10

Difficulty date
August 21, 2020
Submitted
August 24, 2020
Operation
Air carrier
Aircraft
N784QS
Make and model
Bombdr BD1001A10
Aircraft serial
20575
Aircraft time
5,303 hours, 3,019 cycles
Part
Pump
Part number
MLSOA3
Part serial
ADI0315
Condition
Defective
Location
Hyd System
Stage of operation
AP
How discovered
O
Nature of condition
K
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CUAN "R DC HYD FAIL" CAS MESSAGE DURING THE ENTIRE APPROACH PHASE. CHECKED R DC PUMP ON GROUND, GOT RED HYD PRES LOW MESSAGE. 0 PSI IN RIGHT LINE WITH AMBER HYDRAULIC LINES ON HYDRAULIC SYSTEM PAGE. NO B-3 CODE IN SYSTEM. PER FSR, POWERED UP AIRCRAFT APU AND STARTED LEFT AND RIGHT AIRCRAFT ENGINES PER POH. PERFORMED MULTIPLE OPERATIONAL CHECKS OF THE RT DC PUMP WITH NO DEFECTS NOTED. OPERATED THE FLAPS MULTIPLE TIMES NOTING DC PUMPS OPERATED AS REQUIRED. CONTACTED BEN AND WAS ADVISED THE DC ELECTRIC MOTOR 1S AS THE MOST LIKELY CAUSE OF AN INTERMITTENT R HYO DC PUMP FAIL CAS. PER FSR AND MCC, REMOVED SUSPECTED FAULTY RIGHT HYDRAULIC SYSTEM DC ELECTRIC (BRUSHLESS) MOTOR P/T 1 MLGOA-3 S/N ADI0315 AND INSTALLED. REPAIRED DC ELECTRIC (BRUSHLESS) MOTOR P/N T"1L60A-3 S/N ADL0506 IAW CL350 MM CH. 29-12-05. NOTING HYDRAULIC SYSTEM WAS NOT DISTURBED DURING R&R OF DC ELECTRIC (BRUSHLESS) MOTOR. OPERATIONAL CHECK GOOD, PER MCC AND FSR NO FURTHER ACTION IS REQUIRED.