Service difficulty report · Sensor · Gulstm 680

Difficulty date
April 10, 2021
Submitted
April 12, 2021
Operation
Air carrier
Aircraft
N382QS
Make and model
Gulstm 680
Aircraft serial
0245
Aircraft time
11,397 hours, 7,586 cycles
Part
Sensor
Part number
30B570201
Part serial
121604
Condition
Defective
Location
Rt Engine
Stage of operation
CR
How discovered
L
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ENG FIRE DETECT FAIL R AMBER CAS: IN CRUISE FLIGHT AT FL380 AMBER 'ENG FIRE DETECT FAIL R' CAS MESSAGE DISPLAYED. REMOVED INTERNAL FIRE & OVERHEAT SENSOR, PN:- 30B5702-01 ; SN: 121604. FROM RH ENGINE; DUE TO ENG FIRE DETECT FAIL R AMBER CAS MESSAGE DISPLAYED. INSTALLED NEW INTERNAL FIRE & OVERHEAT SENSOR, PN: 30B5702·01 ; SN: 175189, IN RH ENGINE. POST MAINTENANCE OPERATIONAL & LEAK CHECKS PERFORMED WITH NO DEFECTS NOTED. ALL MAINTENANCE ACCOMPLISHED IAW PW306C EMM CH 26-10·01 & 72-00-00.