What was found
LEFT ENGINE GENERATOR: LEFT AC/DC FAILURE IN AMBER. TROUBLESHOT TO SUSPECTED LEFT IDG GROUNDING BRACKET AND FEEDER CABLE ATTACHMENT HARDWARE. NOT ALL PARTS AVAILABLE. COMPILED WITH AQRD RFTS-105208 TO TEMP REPAIR BRACKET FOR PROPER GROUNDING OF E4130B FEEDER CABLE. PERFORMED DIRECT CURRENT LOAD DISTRIBUTION SYSTEM OPERATIONAL CHECK !AW G450 MM CH.24-60-00. RAMPED AIRCRAFT AND STARTED ENGINES IAW THE G450 AFM. PERFORMED LEAK CHECK OF LEFT AND RIGHT ENGINE IDG'S REF G450 MM CH.71-00-00. PERFORMED ENGINE ALTERNATING CURRENT GENERATION OPERATIONAL CHECK IAW G450 MM CH.24-21-00. PERFORMED AC LOAD DISTRIBUTION SYSTEM OPERATIONAL TEST !AW G450 MM CH.24-50-00. OPERATIONAL AND LEAK CHECKS GOOD.