What was found
EMERGENCY LIGHTING: ON POST FLIGHT FOUND THAT ALL OF THE LEFT FORWARD DROPPED AISLE LIGHTING SYSTEM IS NOT WORKING. // SIGNOFF// INSPECTED LH AISLE DROP LIGHTING ELECTRICAL CONNECTOR AND FOUND MOLEX CONNECTOR DISCONNECTED AND 1 WIRE PULLED FROM THE ELECTRICAL CONNECTOR AIRFRAME SIDE. EXTRACTED PIN FROM DROP AISLE LIGHTING CONNECTOR AND CRIMPED BACK ON TO PULLED WIRE IAW CE-560XL SPM 20-30-25. RESEATED CONNECTOR AND PERFORMED SUCCESSFUL OPERATIONAL TEST OF THE AISLE LIGHTING AS REQUIRED. WORK DONE IRW CE-560XL IMM 25-92-1 2.