Service difficulty report · Connector · Cessna 560XL

Difficulty date
August 9, 2021
Submitted
August 10, 2021
Operation
Air carrier
Aircraft
N602QS
Make and model
Cessna 560XL
Aircraft serial
5605518
Aircraft time
14,028 hours, 10,971 cycles
Part
Connector
Condition
Failed
Location
Emergency Lights
Stage of operation
TX
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

EMERGENCY LIGHTING: ON POST FLIGHT FOUND THAT ALL OF THE LEFT FORWARD DROPPED AISLE LIGHTING SYSTEM IS NOT WORKING. // SIGNOFF// INSPECTED LH AISLE DROP LIGHTING ELECTRICAL CONNECTOR AND FOUND MOLEX CONNECTOR DISCONNECTED AND 1 WIRE PULLED FROM THE ELECTRICAL CONNECTOR AIRFRAME SIDE. EXTRACTED PIN FROM DROP AISLE LIGHTING CONNECTOR AND CRIMPED BACK ON TO PULLED WIRE IAW CE-560XL SPM 20-30-25. RESEATED CONNECTOR AND PERFORMED SUCCESSFUL OPERATIONAL TEST OF THE AISLE LIGHTING AS REQUIRED. WORK DONE IRW CE-560XL IMM 25-92-1 2.