As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERG EXIT SIGN/LIGHT: ON POST FLIGHT FOUND THE FORWARD EMER EXIT LIGHT AND FORWARD DROPPED AISLE LIGHT TO BE INOP WITH AND WITHOUT EMERGENCY POWER SELECTED ON. REMOVED AND REPLACED FORWARD EMERAENCY LIAHTS BATTERY PACK. BATTERY CHARAED AND OPS CHECK IS GOOD. REMOVED AND REPLACED DIODE DI051 WITH A NEW PART. OPS CHECK IS QOOD. WORK DONE IAW AMM 33-50-01 AND SPM 20-30-25.