What was found
EMERGENCY LIGHTING: WITH EMERGENCY LIGHT SWITCH OFF AND AIRCRAFT DEPOWERED. THE EMERGENCY LIGHTS OVER THE MAIN CABIN DOOR (WHITE EXIT SIGN), 2 RED LIGHTS AT THE LOWER MAIN CABIN DOOR AND THE LIGHT UNDER THE SEAT ACROSS FROM THE MAIN CABIN DOOR (WHITE FLOOR LIGHT) STAY ON. //SIGNOFF// GAINED ACCESS TO THE NO.1 EMERGENCY LIGHTING INERTIAL SWITCH. RE-SET THE INERTIAL SWITCH AND THE EMERGENCY LIGHTS EXTINGUISHED. RAN THE APU AND CHARGED THE EMERGENCY LIGHTING BATTERIES. PERFORMED OPERATIONAL CHECK OF THE NO.1 INERTIAL SWITCH AND ALL OPERATION IS NORMAL. PERFORMED OPERATIONAL CHECK OF THE EMERGENCY LIGHTING SYSTEM AND ALL OPERATION IS NORMAL AT THIS TIME. ALL WORK WAS PERFORMED IAW CE-680A AMM CHAPTER 33-50-00.