What was found
CABIN EMERG LIGHT: FOLLOWING SHUTDOWN WITH SHIP BATTERIES DISCONNECTED AND EMER LTS SWITCH IN OFF, CABIN ENTRY EXIT SIGN AND FLOOR LIGHT BENEATH SEAT 10 REMAIN ILLUMINATED. (CORRECTIVE ACTION) TROUBLESHOT IAW CE-680A WD 33-50-01 TO ACTIVATED INERTIA SWITCH POS SC001 OF THE FWD. EMERG LIGHTS BATTERY PACK. RESET INERTIA SWITCH AND OPERATIONS RESTORED. PRECAUTIONARY REPLACED INERTIA SWITCH IAW MM 33-50-11. FULLY CHARGED BATTERY PACK. EMERGENCY LIGHTS OPERATIONAL TEST IS NORMAL.