What was found
MAIN DOOR HARDWARE: THE MAIN CABIN DOOR OVER CENTER BAR THAT CONNECTS THE HANDLE TO THE DOOR HAS SHEARED OFF WHEN WE ATTEMPTED TO PULL THE DOOR CLOSED. // SIGN OFF // REMOVED AND REPLACED DOOR LOWER ACTUATING LEVER TUBE ASSY, ROD END, DRIVE ARM, AND HARDWARE IAW CE560XL AMM 52-10-01. OPERATIONAL CHECK OF DOOR SATISFACTORY. NO DEFECTS NOTED.