What was found
EMERG EXIT SIGN/LIGHT: FORWARD EMERGENCY EXIT LIGHTS INOP. FORWARD EMERGENCY LIGHTING BATTERY PACK DEPLETED. REMOVED DAMAGED AMBER EMERGENCY LIGHT "NOT ARMED" LIGHT & REPLACED WITH A NEW LIGHT & LAMP IAW SPM 20-30-30. REMOVED FAILED DIODE DI051 & REPLACED WITH A NEW DIODE IAW SPM 20-30-25. REINSTALLED FORWARD EMERGENCY BATTERY PACK & RECONNECTED THE AFT EMERGENCY BATTERY PACK. CLOSED EMERGENCY & STANDBY CIRCUIT BREAKERS ON EACH BATTERY IN NOSE SECTION. CLOSED CIRCUIT BREAKERS HT043 & HT048 IN THE TAILCONE.CLOSED ALL ACCESSED AREAS AND REINSTALLED CAPTAIN'S SEAT. PERFORMED SUCCESSFUL EMERGENCY LIGHTING OPERATIONAL CHECK IAW AMM 33-50-00 WITH NO DEFECTS NOTED. ALL OPERATIONS AND INDICATIONS NORMAL AT THIS TIME.