What was found
FLOOR EMERG EXIT LIGHT: EMERGENCY LIGHT FLOOR PATH ENTIRE LIGHT UNIT UNDER SEAT FIVE IS INOP BOTH AS EMERGENCY LIGHT AND FLOOR PATH LIGHTING. FOUND WIRES PULLED FROM CONNECTOR UNDER SEAT 5, REINSTALLED WIRES INTO THE CONNECTORS IAW CE680A SPM 20·30·2S, OPERATIONAL CHECK GOOD IAW AMM 33-50·00.