As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR EMERG EXIT LIGHT: LEFT FORWARD FLOOR EMERGENCY LIGHTING INOP. ALL OTHER INTERIOR EMERGENCY LIGHTING IS OPERATIVE. //SIGNOFF// REMOVED AND REPLACED INOPT LH FORWARD MOST AISLE UGHT WITH NEW LED LIGHTING ASSEMBLY. OPS CHECK GOOD. ALL WORK DONE IAW CE560XL AMM 33·20-04. PN (OFF) 9919040-26 , SN (OFF) 121004500, PN (ON) 9919040-29, SN (ON) 124004376