Service difficulty report · Light · Rkwell 700

Difficulty date
November 5, 2022
Submitted
November 8, 2022
Operation
Air carrier
Aircraft
N802QS
Make and model
Rkwell 700
Aircraft serial
7000025
Aircraft time
2,770 hours, 1,625 cycles
Part
Light
Condition
Shorted
Location
Cabin
Stage of operation
TX
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

THE INTERIOR AND EXTERIOR EMERGENCY LIGHT SYSTEM IS NOT OPERSTING PROPERLY. DIFFERENT LIGHTS ARE COMING OFF/ON AT TIMES. CONFIRMED BOTH FUSES FOR SEAT 5 EMERGENCY LIGHT WERE BLOWN. R & R BLOWN FUSE. R & R AFT FUSE. POWERED ON EMERGENCY LIGHTS AND SEAT 5 EMERGENCY PATH LIGHT WORKED FOR A BRIEF TIME BEFORE THE FORWARD AND AFT FUSES BLEW. DISCONNECTED #5 SEAT LIGHT SUSPECTING A SHORTED. REPLACED BOTH FUSES AND POWERED THE EMERGENCY LIGHTS ON FOR SEVERAL MINUTES AND CYCLED THE EMERGENCY LIGHTS MULTIPLE TIMES. RE CHECKED THE FUSES FOR THE SEAT 5 EMERGENCY PATH LIGHT AND THEY ARE STILL GOOD, CONFIRMING A FAULTY EMERGENCY PATH LIGHT.