As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERG EXIT SIGN/LIGHT: EMER EXIT SIGN LIGHT ABOVE THE EXIT WINDOW IS NOT WORKING. NO BULBS LIGHT UP WHEN THE EMER LIGHT SWITCH IS ON.//CORRECTIVE ACTION// FOUND BROKEN OFF WIRES BEHIND AFT EMERGENCY "EXIT" LIGHT. INSTALLED NEW PINS TO WIRES IAW EMBRAER PHENOM 300 SWPM CHAPTER 20 AND WM 33-50-50. OPERATIONAL CHECK GOOD AT THIS TIME.