What was found
FLOOR EMERG EXIT LIGHT: FORWARD LEFT EMERGENCY FLOOR LIGHTING HAS A SECTION OF ABOUT 18" THAT IS NOT FUNCTIONAL. IN THAT 18" RUN, THERE ARE 3 LED'S THAT ARE WORKING. THIS IS LOCATED UNDER OR NEAR SEAT 3. // SIGNOFF// PERFORM OPERATIONAL TEST OF EMERGENCY LIGHT TEST WAS SATISFACTORY, THE TECH CANT DUPLICATE THE FOUL, ALL WORK DONE IN REF CE-560XL AMM 33-50-00