What was found
CABIN EMERG LIGHT: INTERIOR AFT EMERGENCY LIGHTS ARE ILLUMINATED WITH THE EMER LTS SWITCH IN ARM POSITION AND BATTERY SWITCH ON. INTERIOR FORWARD EMERGENCY LIGHTS ARE OFF. ///SIGNOFF/// COMPLIED WITH OPERATIONAL CHECK OF EMERGENCY LIGHTING. CONFIRMED CREW WRITE UP. RESET AFT INTERTIA SWITCH AND OPS CHECKED EMERGENCY UGHTING WITH NO DEFECTS NOTED. CHARGED UP EMERGENCY BATTERIES FOR 2 HOURS. WORK PERFOR??ED IAW CESSNA 560XLS AMM 33-50-00 & 33-50-01.