What was found
MAIN EXIT SIGN/LIGHT: THE LIGHTING ON THE EMERGENCY EXIT SIGN OVER THE MAIN CABIN DOOR IS INOP. REMOVED MED EMERGENCY EXIT SIGN AND INSTALLED NEW CONDITION MED EMERGENCY EXIT SIGN IAW CE680A 33-50-01. REMOVED CONNECTORAND RECEPTACLE JC2066 AND INSTALLED NEW CONDITION CONNECTOR AND RECEPTACLE JC2066 IAW CE680A 5PM 20-30-25. PERFORMED OPS AND FUNCTIONAL CHECKS IAW CE680A AMM 33-50-00. OPS AND FUNCTIONAL CHECKS GOOD WITH NO DEFECTS NOTED.