What was found
MAIN DOOR: MAIN CABIN DOOR ON OPENING, DOOR FALLS WITH VERY LITTLE TENSION UNTIL NEARLY 3/4 WAY OPEN. VERY DIFFICULT TO CLOSE. GAINED ACCESS TO COUNTER BALANCE MECHANISM. FOUND FWD AND AFT CABIN DOOR SPRINGS IN SERVICEABLE CONDITION. DURING CABLE ADJUSTMENT FOUND FWD DOOR CABLE FRAYED BEYOND LIMITS AND MISSHAPEN. WORK DONE IAW 560XL MM 52-10-03. ORDERED DOOR CABLE REMOVED AND REPLACED FWD CABLE. ADJUSTED BOTH CABLES AS REQUIRED IAW 560XL MM 52-10-03. INSTALLED STEPS. FINAL OP'S CHECK GOOD.