What was found
MAIN DOOR: MAIN DOOR EXTREMELY DIFFICULT TO CLOSE FROM THE INSIDE. THE HANDLE CLOSES FINE THE FIRST 45 DEGREES THEN MEETS VERY STIFF RESISTANCE. THE MAIN DOOR CLOSES FINE FROM THE OUTSIDE. //SIGNOFF// FOUND THE MED LATCH PLATES OUT OF ADJUSTMENT PERFORMED THE LATCH PLATE ADJUSTMENT PROCEDURE ON THE AFT CENTER, AFT LOWER, AND FWD CENTER MAIN ENTRY DOOR LATCHING PLATES. OPERATIONAL CHECKS GOOD, ALL WORK PERFORMED IN REFERENCE TO CE·S60XLS AMM 52-10-00, PERFORMED LUBRLCATION AS REQUIRED TO LOCKING PINS, REF, MM 52-10•00,