EMERGENCY LIGHTS BLINKING FOR THE LAST 35 MIN OF FLIGHT IN TO SDL. COMPLIED WITH FIM TASK 33-50-00-810-802-A. FOUND WITH ELECTRICAL CONNECTOR P1360 DISCONNECTED, EMERGENCY LIGHTS DO NOT COME ON IN ARM POSITION. PER FIM TASK, REPLACEMENT OF THE EMERGENCY LIGHT BATTERY 2 IS REQUIRED. BATTERY PLACED ON ORDER BY CUSTOMER. PERFORMED WORK IAW EMBRAER 505 FIM CH. 33-50-00-810-802-A. (JH-12/18/23) REMOVED AND REPLACED AFT EMERGENCY BATTERY WITH "NEW" IAW PHENOM 300 MM 33-52-01-400-801-A. ALL FOLLOW ON CHECKS PASS WITH NO DEFECTS NOTED.