What was found
EMERGENCY LIGHTING: LAST TWO MORNINGS HAD TO CHARGE THE EMERGENCY BATTERIES FOR 30 MINUTES TO GET A SATISFACTORY TEST GAINED ACCESS TO FORWARD EMERGENCY BATTERY INERTIA SWITCH AND RESET IAW CE680A MM CH. 33-50-11. POWERED AIRCRAFT AND ALLOWED EMERGENCY BATTERIES TO CHARGE FOR 2 HOURS. PERFORMED OPERATIONAL TEST OF THE EMERGENCY LIGHTING SYSTEM IAW CE680A MM CH. 35-50-00 WITH NO DEFECTS NOTED. OPERATIONAL CHECK GOOD.