What was found
WHEN TESTING THE EMERGENCY LIGHTS THEY COME ON IN THE ON POSITION, HOWEVER THEY GO OUT IN THE ARM POSITION WHEN THE BATTERIES ARE OFF. PERFORMED TC·FLT-33-1001 REV 2 AND BATTERIES CHECKED GOOD. BATTERIES TURN ON IN BOTH THE ON AND ARM POSITION WITH THE BATTERIES OFF.