Service difficulty report · Fuse · Textrn TEXTRON700

Difficulty date
September 28, 2024
Submitted
October 1, 2024
Operation
Air carrier
Aircraft
N839QS
Make and model
Textrn TEXTRON700
Aircraft serial
7000084
Part
Fuse
Condition
Blown
Location
Zone 200
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER SHUTDOWN/BATTERIES DISCONNECT EMERGENCY LIGHTS DO NOT TURN OFF. RE-OPEN MCD, PROCEEDED TO DO THE 5G RESETS. EMERGENCY LIGHTS DO NOT TURN OFF. RE-CONNECT BATTERIES TO CLOSE MCD. MCD DOESNT CLOSE FROM THE OUTSIDE OR INSIDE. SINCE BATTERIES ARE CONNECTED. TURN BOTH BATTERIES SWITCH IN COCKPIT. MCD IS WORKING AGAIN. TURN BATTERIES OFF. EXIT PLANE. CLOSE MCD. DISCONNECT BATTERIES. THEN EMERGEMCY LIGHTS TURNED OFF. CORRECT ACTION: REMOVED AND REPLACED #4 EMER BATTERY FUSE RESET INTERIAL SWITCHES EMER LIGHTS OPS CHECKS GOOD REF MODEL CE-700 AMM 33-50-05-33-50-00 MJA TASK CARD TC-FLT-33-1001 REV. 2 DATED 20OCT2022.