Service difficulty report · Battery Pack · Textrn TEXTRON700

Difficulty date
March 2, 2025
Submitted
March 5, 2025
Operation
Air carrier
Aircraft
N847QS
Make and model
Textrn TEXTRON700
Aircraft serial
7000096
Aircraft time
1,794 hours, 1,083 cycles
Part
Battery Pack
Part number
CBS281
Part serial
009022
Condition
Defective
Location
Zone 200
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WITH BATTERIES OFF AND NOT ON SHIP POWER, EMERGENCY LIGHTS DO NOT COME ON WHEN SWITCHED TO THE ON POSITION. EMERGENCY LIGHTS DO COME ON WHEN SWITCHED TO THE ARM POSITION, WHEN NOT ON SHIP POWER. ONCE EMERGENCY LIGHTS HAVE TURNED ON WITH THE SWITCH IN THE ARM POSITION, THEY WILL STAY ON IF THE SWITCH IS TURNED TO ON. WHEN ON SHIP POWER (BATT ON, OR BATT AND GPU ON, EMER BUSSES POWERED), EMERGENCY LIGHTS WILL TURN ON WITH THE EMERGENCY LIGHT SWITCH IN THE ON SWITCH POSITION. EMERGENCY LIGHTS BATTERY PACKS HAD TIME TO FULLY CHARGE. SUSPECT THE NUMBER THREE EMERGENCY LIGHT BATTERY IS FAULTY. CORRECTIVE ACTION; REMOVED AND REPLACED AFT EMERGENCY BATTERY PACK !AW CE700 AMM 33-50-05, PERFORMED OPERATIONAL CHECK IAW CE700 AMM 33-50-00. OPS CHECKS GOOD