What was found
EMERGENCY LIGHTING: WITH BATT'S ON, EMER LIGHT SWITCH OFF, THE EMER LIGHTS REMAIN ILLUMINATED, CHECKED BOTH 5G SWITCHES. CORRECTIVE ACTION; RESET ALL 4 G SWITCH SIMULTANEOUSLY AND RESET EMERGENCY BATTERY SYSTEM. PERFORMED SATISFACTORY OPERATIONAL TEST. ALL WORK IAW CE-700 AMM 33-50-00, 33-50-10.