Service difficulty report · Light · Emb EMB505

Difficulty date
May 29, 2025
Submitted
May 30, 2025
Operation
Air carrier
Aircraft
N325QS
Make and model
Emb EMB505
Aircraft serial
50500168
Aircraft time
10,120 hours, 7,857 cycles
Part
Light
Condition
Dim
Location
Zone 200
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

VARIOUS CABIN FLOOR EMERGENCY LIGHTS FAIL TO ILLUMINATE. THE RED EMERGENCY EXIT FLOOR LIGHT, ADJACENT WHITE FLOOR LIGHT, DO NOT ILLUMINATE. THE LAV EMERGENCY FLOOR LIGHT IS VERY DIM/OBSCURED. THERE IS AN INCORRECT RED FLOOR LIGHT AT CLUB SEATING AREA, THIS SHOULD BE WHITE. THERE IS NO RED EMERGENCY FLOOR LIGHT AT THE MAIN ENTRY DOOR, IT IS WHITE INSTEAD. CORRECTIVE ACTION: REMOVED AFT DIM EMERGENCY FLOORLIGHT P/N 0434LS00-01 NSN AND INSTALLED NEW CUSTOMER SUPPLIED LIGHT P/N 0434LS00-01 NSN. FOUND FAULTY MID EMERGENCY LIGHT, REMOVED EMERGENCY LIGHT P/N 0434LS00-01 NSN AND INSTALLED NEW CUSTOMER SUPPLIED LIGHT 0434LS00-01 NSN. RESTORED ALL FLOOR LIGHT TO THE ORIGINAL CONFIGURATION. OPS CHECK GOOD. ALL WORK DONE IN REFERNCE TO EMBRAER PHENOM AMM 33-52-00