Service difficulty report · Battery Pack · Cessna 560XL

Difficulty date
September 14, 2025
Submitted
September 17, 2025
Operation
Air carrier
Aircraft
N566QS
Make and model
Cessna 560XL
Aircraft serial
5605825
Aircraft time
14,673 hours, 11,107 cycles
Part
Battery Pack
Condition
No Test
Location
Zone 200
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ALL FORWARD EMERGENCY EXIT LIGHTS INOP IN ARM OR ON POSITION WITH BATTERY OFF. BATTERY PACK #1 RESET INERTIAL SWITCH VERIFIED CONNECTIONS TO BATTERY PACK #1 ARE GOOD, NO CHANGE, ALL FORWAR LIGHTING STILL INOP, SWAPPED BATTERY PACK #2 AND REPOSITIONED INTO #1. PERFORMED OPS ALL FWD LIGHTING FULLY OPS. ALL WORK DONE IAW AMM 33-50-00. INSTALLED BATTERY PACK #2 BACK TO ITS ORIGINAL POSITION , #1 REQUIRES REPLACEMENT. REMOVED FWD BATTERY PACK AND REPLACED WITH AN OVERHAULED BATTERY PACK. POWERED UP THE ACFT WITH AN EXTERNAL GPU ELECT POWER & CHARGED BATTERY PACKS FOR 1.75 HOURS, PERFORMED BATTERY PACKS FUNCTIONAL CHECK. BATTERY FUNCTIONAL CHECK & EMER LIGHTS OPS CHECK PASSED. WORK PERFORMED IAW AMM 33·50-01 & 33-50·00..