Service difficulty report · Shutoff Valve · Bombdr BD7001A11

Difficulty date
November 28, 2025
Submitted
December 1, 2025
Operation
Air carrier
Aircraft
N132QS
Make and model
Bombdr BD7001A11
Aircraft serial
60137
Aircraft time
827 hours, 427 cycles
Part
Shutoff Valve
Condition
Faulted
Location
Brake Sys
Stage of operation
AP
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

THE BRAKE 50% DEGRADED & AUTO BRAKE FAIL AMBER CAS MESSAGE CAME ON SHORTLY AFTER GEAR EXTENSION. INTERROGATED OMD DATA FOR FAULTS AND SENT BRAKE SYS OMS DOWNLOADS TO MCC FOR REVIEW. INTERROGATED OMD DATA FOR FAULTS & SENT FAULT MESSAGE OMS DOWNLOADS TO MCC FOR REVIEW. R&R OTBD BRAKE SHUTOFF VALVE CONDITION: OVERHAULED IAW AMM 32-43-25. BLED & LEAK CHECKED NR 2 HYD SYS IAW AMM 29-10-00. OPS CHKD GOOD.