Service difficulty report · Battery Pack · Bombdr BD7001A12

Difficulty date
December 4, 2025
Submitted
December 5, 2025
Operation
Air carrier
Aircraft
N186QS
Make and model
Bombdr BD7001A12
Aircraft serial
70186
Aircraft time
1,050 hours, 360 cycles
Part
Battery Pack
Condition
Discharged
Location
Zone 200
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SEVERAL EMERGENCY LIGHTS NOT WORKING. INTERIOR RIGHT SIDE OF AIRCRAFT ON FLOOR LIGHTING BOTH EXTERIOR OVER WING EMERGENCY LIGHTS NOT WORKING. DEBRIEFED THE CREW EARLIER, AND UPON POWER-UP, WE FOUND THAT ELPS 2 WAS NOT ILLUMINATING THE DESCRIBED EMERGENCY LIGHTS. WE ALLOWED THE ELPS #2 TO CHARGE, PERFORMED THE OPERATION TEST PROCEDURE FOR THE EMERGENCY LIGHTING POWER SUPPLIES I.R.W. GL-7500 AMP BD700-A-J33-51-00-02AAA-320E-A, AND THE TEST WAS FOUND SATISFACTORY. ADVISED NJA MCC, AND THEY STATED IT WAS OK TO RELEASE.