As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY FLOOR EXIT LIGHTS NOT WORKING ON RIGHT SIDE OF AIRCRAFT. TWO OVER WING EMERGENCY EXIT LIGHTS NOT WORKING. DEBRIEFED THE CREW EARLIER, AND UPON POWER-UP, FOUND THAT ELPS 2 AND ELPS 4 WERE NOT ILLUMINATING DESCRIBED EMERGENCY LIGHTS. ALLOWED THE ELPS 2 & ELPS 4 TO CHARGE PER CUSTOMER'S REQUEST, & PERFORMED THE OPS TEST PROCEDURE FOR THE EMERGENCY LIGHTING POWER SUPPLIES IAW AMP BD700-A-J33-51-00-02AAA-320B-A. OPS TEST FOUND SATISFACTORY. OK TO RELEASE.