Service difficulty report · Battery Pack · Emb EMB505

Difficulty date
February 2, 2026
Submitted
February 4, 2026
Operation
Air carrier
Aircraft
N419QS
Make and model
Emb EMB505
Aircraft serial
50500461
Aircraft time
7,223 hours, 5,743 cycles
Part
Battery Pack
Condition
Discharged
Location
Zone 200
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHEN EMERGENCY LIGHTS ARE IN ARMED POSITION, ALL EMERGENCY LIGHTS ILLUMINATE. THEN AFTER A FEW MINUTES ALL LIGHTS START TO FLASH. SET BATTERY SWITCH TO ARM POSITION. EMERGENCY LIGHTS ILLUMINATED FOR ABOUT ONE MINUTE, FLASHED THEN EXTINGUISHED. CHARGED BATTERIES FOR 30 MINUTES. WITH BATTERIES OFF, SWITCH TO ARM, LIGHTS ILLUMINATED FOR 10 MINUTES WITH NO OTHER DEFECTS NOTED AT THIS TIME. POWER WAS APPLIED AND SWITCH SET BACK TO ARM TO CHARGE FOR ANOTHER 30 MINUTES, TESTED AGAIN WITH NO DEFECTS NOTED AT THIS TIME. ALL WORK WAS PERFORMED IAW MM 33-52-00