As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AMBER DOOR CLOSED LED ON MAIN CABIN DOOR INOP. THE AMBER DOOR LED TURNS OFF WHEN THE DOOR IS CLOSED WITH THE DOOR HANDLE IN THE OPEN POSITION. THE AMBER LED TURNS OFF WHEN THE DOOR IS ABOUT HALF WAY UP. CORRECTIVE ACTION: REMOVED HARNESS ASSY CAB DOOR THRESHOLD PN 8250171-1 AND INSTALLED A NEW HARNESS ASSY CAB DOOR THRESHOLD PN 8250171-1. REF: MODEL 700 MAINTENANCE MANUAL 52-10-00. NO FURTHER DEFECTS NOTED AND OPS CHECK IS GOOD.