Service difficulty report · Smoke Detector · Textrn TEXTRON700

Difficulty date
March 4, 2026
Submitted
March 6, 2026
Operation
Air carrier
Aircraft
N806QS
Make and model
Textrn TEXTRON700
Aircraft serial
7000029
Aircraft time
6,225 hours, 3,641 cycles
Part
Smoke Detector
Condition
Dirty
Location
Zone 100
Stage of operation
TX
How discovered
V
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON GROUND GOT RED BAGGAGE FIRE LIGHT CAS MESSAGE. POWERED UP ACFT & ABLE TO DUPLICATE DISCREPANCY, WENT THRU FAULT HISTORY & FOUND ALERT ID 593. THIS FAULT IS TRIGGERED WHEN AFT CARGO SMOKE DETECTOR INPUT TO GSD2 INDICATES SMOKE DETECTED. IAW TROUBLE SHOOTING GUIDE AMM 26-12-00. FOUND SMOKE DETECTOR FAILED RED LIGHT ON, & FWD DETECTOR RED LIGHT OFF. VERIFY & FOUND POWER ON CONNECTOR, BUT SYS TEST FAILED. REMOVED AFT SMOKE DETECTOR, FOUND COVER WITH DUST, CLEANED, VERIFY CONNECTION PINS & FOUND OK, INSTALLED SMOKE DETECTOR (UCI0I) IAW AMM 26-12-05 & RED LED LIGHT OUT. PERFORMED AFT CARGO SYS OPS CHECK IAW AMM 26-12-0D, SYS WORKING PROPERLTY, NO RED CARGO FIRE LIGHT, NO CAS MESSAGE. OPS CHECK OK