What was found
EMERGENCY LIGHTS STAY ON WHEN EMERGENCY LIGHTING SWITCH PLACED IN THE ARMED POSITION. RECYCLED POWER ON AIRCRAFT WITH SAME RESULTS. ACCESSED AFT EMERGENCY LIGHTING BATTERY PACK, REMOVED ACCESS PANEL LOCATED IN AFT L/H SIDE CLOSET, FOUND G SWITCH TRIGGERED ON BATTERY PACK P/N 9913-1 S/N 675, RESET "G SWITCH"PERFORMED EMERGENCY LIGHTING OPERATIONAL CHECK, ALL CHECKS GOOD, NO FAULTS FOUND, CLOSED ACCESS PANEL IN L/H AFT CLOSET, RETURNED AIRCRAFT TO INITIAL CONDITION, REF CE 560XL AMM 33-50-01