What was found
MAIN ENTRY DOOR CLUNKS TOWARD THE TOP OF CLOSING AND HANGS UP. DOES NOT FREE FALL ON UNLATCH AND MUST BE PUSHED OPEN. PERFORMED ADJUSTMENT TO THE MED STEP FORWARD AND AFT PANELS AND BOTTOM STEP PAD. CHECKED GAP CLEARANCES OF MED AND AIRFRAME STRUCTURE GUIDE PADS. CLEANED CONTACT SURFACES OF MED AND AIRFRAME STRUCTURE. NO ACTUAL INTERFERENCE OR DEFECTS NOTED IN DOOR FUNCTION AT THIS TIME. PERFORMED IAW CE-680AS MM 52-10-00.