As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CABIN ENTRY DOOR IS VERY HARD TO OPEN AND CLOSE. IT IS HITTING METAL WHEN ATTEMPTING TO CLOSE. DON'T KNOW IF ITS RELATED TO THE CHECK DOOR MEL. OPERATED MAIN CABIN DOOR NUMEROUS TIMES WITH NO DEFECTS NOTED,(HARD TO OPEN OR CLOSE OR METAL HITTING). ALSO PERFORMED MAIN CABIN DOOR HEALTH CHECK/ DATA COLLECTION CHECK LIST AND SEND TO TEAM680@TXTAV.COM FOR DOCUMENTATION. REF CE-680A AMM 52-10-04.