Service difficulty report · Modulating Valve · Emb EMB500

Difficulty date
December 3, 2015
Submitted
December 7, 2015
Operation
Air carrier
Aircraft
N665AS
Make and model
Emb EMB500
Aircraft serial
50000018
Aircraft time
3,856 hours, 3,234 cycles
Part
Modulating Valve
Part number
130033011
Condition
Stuck
Location
Ac Bay
Part time
3,856 hours, 3,234 cycles
Stage of operation
CL
How discovered
O
Nature of condition
B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAKEOFF, CREW NOTED HOT SMELL & A SMALL BIT OF SMOKE IN THE CABIN. TURNED OFF RT BLEED VLV, SMOKE & HOT SMELL DISSIPATED. DETERMINED RT CABIN TEMP MODULATING VLV WAS STUCK OPEN. INSTALLED NEW VLV, GND RUN & OPERATIONS CHECK WERE SATISFACTORY. ACFT WAS RETURNED TO SERVICE.