What was found
UPON OK TO CLOSE, FOUND EXFOLIATED LOWER FWD STRINGER INSIDE FUEL ACCESS PANEL 514D, INBOARD END. REMOVED STRINGER 59. FABRICATED STRINGER 59 REPAIR SPLICE FITTING. INSTALLED IAW SRM & EA 008-5710-38-A6042.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UPON OK TO CLOSE, FOUND EXFOLIATED LOWER FWD STRINGER INSIDE FUEL ACCESS PANEL 514D, INBOARD END. REMOVED STRINGER 59. FABRICATED STRINGER 59 REPAIR SPLICE FITTING. INSTALLED IAW SRM & EA 008-5710-38-A6042.