What was found
DURING THE MAINTENANCE INSPECTION PROCESS IT WAS FOUND AT THE UPPER FUSELAGE, MAIN CARGO DOOR SURROUND, B/S 500C, BETWEEN STR 6L AND STR 7L, FUSELAGE STRAP WITH AN ELONGATED FASTENER HOLE. THE AFFECTED STRAP IS REPAIRED UNDER EO4412-4 AND APPROVED BY 8110-3.