What was found
DURING THE STRUCTURAL INSPECTION IN THE FWD CARGO BAY AREA, FOUND AT BS 540, THE STRINGER 27L WITH THE END FITTING CORRODED. THE DAMAGED END FITTING WAS REPLACED IAW SRM 51-10-02, PARAGRAPH 8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.