What was found
LOWER FWD FUSELAGE, BETWEEN FR15 AND FR17, BETWEEN STRINGER 20L AND STRINGER 23L, EXISTING SKIN REPAIR WITH UPPER LAST ROW FASTENERS OVER SUB-STRUCTURE ON STRINGER 21L. FURTHERMORE, THE REPAIR IS COMMON TO 4EA LIGHTNING STRIKES LOCATED AT FR14+240MM ABOVE STRINGER 21L. NOTE: THE SKIN WAS REPAIRED AS PER EMBRAER TECHNICAL DISPOSITION ETD2021-190-020177 DATED JUL 01, 2021 (REF: JOB: A1K020 NON ROUTINE ITEMS: 1-27 AND 1-101).